Fuji Xerox ApeosPort-II C4300(AP)Series Security Kit for Asia Pacific Security Target V1.01
- 18 -
2.7.2. Non-Security Function of TOE
TOE provides the following non-security functions.
Function classification Description
Copy control function Function to control copy operation of MFP. Document data scanned in IIT
is converted to image data such as through digital filter and printed out by
IOT.
Printer control function Function to control printer operation of MFP. Print data described in page
description language (PDL) is sent from user’s client. This data is
converted to bitmap data by decomposing function so that it can be printed,
and printed out by IOT.
Decomposing function Used in printer function. Function to parse print data that is described in
page description language (PDL) and sent from user’s client and to convert
the data to bitmap data so that it can be printed out.
Scanner control function Function to control scanner operation of MFP. Document data scanned in
IIT is converted to image data such as through digital filter and stored on
the hard disk drive.
Facsimile control function Function to control facsimile operation of MFP. Document data scanned in
IIT is converted to image data such as through digital filter and sent to a
remote-machine connected to public telephone line network. Document
data sent from a remote-machine connected to public telephone line
network is printed out by IOT.
CWIS Function to check the status of consumables etc. of MFP using the Web
browser and to read/write various setting data.
2.8. How to Use TOE
TOE setting data is set by key operator. After being authenticated by entering the default
key-operator’s user ID, which is set at the shipment, at the control panel, key operator makes
settings on the setting items described below. Only the “changing of key-operator’s password”
described below can be set from key-operator’s client.
- Setting for using password
Set to “Perform.”
- Changing of key-operator’s password
Set 7 to 12 alphanumeric characters other than the default password.
- Setting for access denial due to failure in authentication of key-operator’s ID
Set to “5.”
- Setting for customer-engineer operation restriction function
Set to “Perform.”
- Setting for HDD overwriting function for residual data
Set to “Perform (one time)” or ”Perform (three times).”
- Setting for HDD data encryption function
Set to “Perform.”
- Setting for cryptographic seed key for data stored on the hard disk drive
Set 12 alphanumeric characters. (When 11 or fewer characters are set, “0” is automatically set for the
shortage.)
When general user uses copy and printer functions of MFP, used document data is stored on the